Petro-SIM 7.1 SP1 Changelist
List of enhancements included in this service pack
EBR-SIM
- Expose/incorporate sedimentation calc.
- Add results from the calculated Recycle Pump head
- Add Decat Feed/FCC CO feed
REF-SIM
- Remove Regen up/down option from GUI
- R3 effluent bypass to R4
ULSD
- Catalyst deactivation imrpovement, by adding a new ULSD catalyst aging mechanism and GUI updates
DC-SIM
- Ability to alter the Watson K threshold used to determine straight-run vs. cracked feed
- Addition of a new method under furnace cracking calculation method to correct coke yield vs, feed temperature response
NHTR
- NHTR to handle C4- components in feed
List of bug fixes included in this service pack
SIM Suite Reactors Models - AROM-SIM
Defect | Description |
17192 | Unresolvable inconsistency errors loading 62 AROM cases into 71 |
SIM Suite Reactors Models - DC-SIM
Defect | Description |
17433 | Default Ca Cn Estimation Method not ideal in Coker Synthesis settings in wizard base case |
16793 | DC-SIM returning different results based on feed stream order when non-Tray 1 feeds present |
15688 | The report of drum vapor to fractionator inlet temperature is wrong when no quench is applied |
15314 | The sulfur and nitrogen contents in feed 6 are not counted in the S and N balances |
SIM Suite Reactors Models - EBR-SIM
Defect | Description |
17403 | Add Collaboration tool feature to EBR-SIM |
16880 | Catalyst Makeup Rate has the wrong varID in WB/KB |
SIM Suite Reactors Models - FCC-SIM
Defect | Description |
17692 | CDB: FCC allows to select the catalyst but it deletes the file before reading it on calibration |
17521 | FCC Monitor Reactor fails while migrating an UMT to v7.1 |
16970 | FCC-SIM: ZSM5 factors not updated if next to the identifier there is something written |
14709 | To allow the new ZSM5 v7 kinetic method work even if reactor dilute phase V is empty or zero |
12045 | Missing Sulfur content in all products results in -32767 passed in FXDATA and calibration failure |
SIM Suite Reactors Models - HXX-SIM
Defect | Description |
17725 | HXX: Deprecated reactor-wide cracking selectivity factors showing up in Application Workbook |
17559 | HXX: Pressure drop cat shape *actually* erroneously swapped “sphere” vs. “cylinder” this time |
17436 | Sulfur Imbalance in NHTR-SIM |
17390 | HCR 2-Stage without liquid recycle to R3 caused internal crash |
17222 | CNHTR-SIM Sulfur Shift reactor generates large positive net yield for Mercaptan Sulfur |
16861 | HXX pressure drop mistakenly error out when R1 tops cat height is larger than R1 B1 cat height |
16859 | Calibration falsely failed due to division by zero within the pressure drop code |
16824 | Division by zero causes unexpected error of flash h2 in liq goes NaN |
16787 | Poly-aromatics rector validation step prevents calibration |
16746 | CNHTR-SIM S/N override only works for 2rx config (diolesat/deS) but not single-rx (selective hds/sulfur shift) |
16720 | HXX: Error #125 for heat balance problems obscures real cause of calibration failure |
16718 | HXX: Error #47 blames the wrong reactor and bed for data issues |
16717 | HXX: Crash when new quench control enabled and # of R2 beds exceeds R3 beds |
16646 | Cold predict failed even though calibration/back-predict/primed-predict succeeded with the same input data |
SIM Suite Reactors Models - OLEFIN-SIM
Defect | Description |
17574 | Pyrolysis furnace Hydrotreated Gas Oil gives invalid feed composition error |
17501 | Furnace handles gas oil incorrectly in split coil case |
SIM Suite Reactors Models - REF-SIM
Defect | Description |
17595 | REF: The range suggested in the yield test warning message may not be accurate for some severities |
16263 | Need to update the Ref-SIM manual for calibration |