Petro-SIM 7.0 SP1 Changelist
List of bugs fixed included in this service pack
SIM Suite Reactors Models - General Reactors
Defect | Description |
15069 | Case with reactor saved in monitoring mode always recalls to calibration mode |
SIM Suite Reactors Models - HXX-SIM
Defect | Description |
14892 | DHTR-SIM in ULSD Mode – Issue with aromatics inhibition |
14909 | Don’t error out when makeup H2 purity is lower than treat gas |
14951 | Petro-SIM error messages when opening VGO HTR-SIM reactor object |
15004 | HCR 2-Stage not meeting Overall Conversion target but still reported converged |
15129 | Validation results of LHSV and catalyst density is missing |
15131 | Wizard base cases need to have default Catalyst Database loaded |
15152 | NHTR Pure Comp mode will not crack super light feed |
15156 | NHTR pure comp mode generates bad effluent comps (only C5 material) when feed is super light (iCNTop<9) |
15195 | HXX: Predict runs using wrong Catalyst Activity Option, making the wrong variables mandatory |
15453 | RHDS MOC stops accumulating .... “selectively” |
14835 | HXX-SIM Restructuring – Phase I – GUI Changes – Values displayed do not match |
15211 | DHTR in monitoring mode aborts when a view is opened |
14616 | Poisons (Si/Ar) % removal should have dropped to zero when maximum capacity uptake is reached |
15026 | VGOHTR: Incorrect Calculated Factors -> Reactors view when in Monitoring or Calibration mode |
15048 | HXX CDB Excel Workbook Editor: Exported XML uses “0” values for empty variables on the Editor sheet |
15113 | ULSD case failed because the default tuning factors did not load for predict |
15130 | Warning #44 “Issues with kinetic constants factors out of range” needs to be improved |
15187 | HXX CDB Excel Workbook Editor: Error when importing XML file after having already imported one |
15304 | HXX Catalyst Selection by bed is missing from Calib/Predict Results tab |
SIM Suite Reactors Models - FCC-SIM
Defect | Description |
14960 | FCC-SIM calibration gets stuck if validation fails and calibration is run subsequently |
14857 | FCC RON and MON profiles not populated |
14894 | nC5 yield not matched in calibration due to ZSM-5 |
13420 | Investigate why note 66 and 67 are being called in v7 FCC Sample |
14022 | Meter variables for delta SG not used by synthesis |
14961 | Normalization mode with monitoring reactor as source gives consistency errors |
SIM Suite Reactors Models - DC-SIM
Defect | Description |
15247 | DC-SIM sensitivity to feed distillation |
15186 | DC-SIM Calibration issue |
15324 | Coker does not solve with zero flow feed |
SIM Suite Reactors Models - REF/AROM/ISOM-SIM
Defect | Description |
14989 | ISOM-SIM wizard loses Separator Gas composition in meter for once-through gas configuration |
13656 | AROM-SIM calibration validation case highlighting calibration noise |
13988 | Sporadic Noise during Isom Reactor Calibration |
14584 | ISOM-SIM failed without generating any useful message (V62 complained about unable to calculate RON/MON) |
14622 | AROM-SIM failed to update calibration factors |
14610 | ISOM integrated-step-optimizer lacks the ability to disable or even remove a step |
15205 | REF-SIM pilot plant mode / once-through hydrogen does not properly calibrate |
15303 | AROM-SIM erroneously generated Note #19 about missing catalyst density |
15325 | AROM-SIM falsely complain about mismatched octane blending method |
15400 | ISOM-SIM should not use the REF-SIM mX, pX, oX factors |
14844 | Badly declared low bound for cat circ loop2 caused Primed Predict to fail only in back predict mode |
15381 | Spreadsheet Values are empty after Calibration |
SIM Suite Reactors Models - ALK-SIM
Defect | Description |
15065 | ALK-SIM generated synthesis error about leaded octane |
15189 | ALK-SIM reportee Residue (C12+) is actually C9+ |